{"id":410,"date":"2026-08-12T16:43:40","date_gmt":"2026-08-12T11:13:40","guid":{"rendered":"https:\/\/www.hicplates.com\/blog\/?p=410"},"modified":"2026-08-12T16:51:26","modified_gmt":"2026-08-12T11:21:26","slug":"astm-a516-gr-60-nace-mr0103-plates-testing","status":"publish","type":"post","link":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/","title":{"rendered":"ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing"},"content":{"rendered":"<h2><b>ASTM A516 Gr. 60 NACE Plates and Sour-Service Testing<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Wet H\u2082S environments break down ordinary carbon steel from the inside out. <\/span><b>ASTM A516 Gr. 60 NACE MR 0103 Plates<\/b><span style=\"font-weight: 400;\"> answer this problem in pressure vessels, separators and process equipment where sour service is part of daily operation. Hydrogen atoms generated by H\u2082S corrosion enter the steel and collect at internal defects, and three distinct cracking mechanisms follow from that entry: HIC, SSC\/SSCC and SOHIC. Each one behaves differently, and each demands its own test method. <\/span><a href=\"https:\/\/www.hicplates.com\/astm-a-516-gr-60-nace-mr-0103-0175-plates-supplier-stockist.html\"><b>ASTM A516 Gr. 60 NACE MR 0103 \/ MR0175 Plates<\/b><\/a><span style=\"font-weight: 400;\"> are manufactured and tested against these exact requirements.<\/span><\/p>\n<h2><b>Why Sour-Service Testing Matters for A516 Gr. 60 Plates<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">H\u2082S reacts with the steel surface and releases atomic hydrogen as a corrosion byproduct. Hydrogen does not stay on the surface. It diffuses into the steel matrix and accumulates at inclusions, laminations and other internal discontinuities, building pressure inside the microstructure. Left unchecked, this process cracks the plate from within, often without any visible surface warning. <\/span><b>ASTM A516 Grade 60 HIC Plates<\/b><span style=\"font-weight: 400;\"> are produced with controlled sulphur content and clean steelmaking practices specifically to limit the internal defects where hydrogen can concentrate. Testing confirms whether that control actually worked.<\/span><\/p>\n<h2><b>HIC Testing: What Does NACE TM0284 Evaluate?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Hydrogen-Induced Cracking, or HIC, forms when trapped hydrogen builds enough internal pressure to crack the steel between inclusions, parallel to the plate surface, without any external stress applied. <\/span><b>NACE TM0284<\/b><span style=\"font-weight: 400;\"> is the laboratory test method written specifically to evaluate this mechanism. A steel specimen sits in a controlled solution containing H\u2082S under defined exposure conditions, then gets sectioned and examined for cracking. Three ratios come out of that examination: Crack Length Ratio (CLR), Crack Thickness Ratio (CTR) and Crack Sensitivity Ratio (CSR). These figures describe how much cracking occurred and how severe it was, and the applicable project specification sets the acceptance limits against them. <\/span><b>A516 Gr. 60 HIC Tested Plates<\/b><span style=\"font-weight: 400;\"> carry documented CLR, CTR and CSR values on their test reports, giving buyers a traceable basis for acceptance rather than a bare pass\/fail claim. <\/span><b>NACE MR0103 Plates<\/b><span style=\"font-weight: 400;\"> reference this test as part of their qualification for sour-service equipment used in oil and gas production and refining.<\/span><\/p>\n<h2><b>SSC or SSCC Testing: How Is It Different From HIC?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Sulfide Stress Cracking, commonly abbreviated as SSC or SSCC, is a fundamentally different issue. Where HIC needs no applied load, SSC requires both H\u2082S exposure and tensile stress acting together on the material. <\/span><b>NACE TM0177<\/b><span style=\"font-weight: 400;\"> is the standard laboratory method for this evaluation, typically run using constant-load, tensile or bent-beam specimens held under stress in an H\u2082S environment for a fixed duration. A specimen that survives the test period without failure passes; one that cracks under load does not. This is the key distinction buyers need to hold onto: HIC testing checks for cracking without stress, while SSC testing checks for cracking specifically because of stress. <\/span><b>NACE MR0175 Plates<\/b><span style=\"font-weight: 400;\"> are qualified with SSC resistance as a core requirement, since this standard governs materials for oil and gas equipment operating directly in sour environments under load.<\/span><\/p>\n<h2><b>SOHIC: Understanding Stress-Oriented Hydrogen-Induced Cracking<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Stress-Oriented Hydrogen-Induced Cracking, or SOHIC, sits in the space between the other two mechanisms. It involves hydrogen-assisted cracking that develops in a stacked, stress-oriented pattern rather than the scattered pattern typical of standard HIC damage, and it is influenced by the local stress field around welds and other high-stress zones. A plate marked HIC tested has not automatically demonstrated resistance to SOHIC, SSC, or any other sour-service degradation mode. Each mechanism has its own driving conditions and its own test method, so buyers should confirm exactly which mechanism a test report addresses rather than assuming broad coverage from a single certificate. Where SOHIC resistance is a project requirement, the applicable test method and acceptance criteria should be confirmed against the governing specification before order placement.<\/span><\/p>\n<h2><b>HIC vs SSCC vs SOHIC: Key Testing Differences<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Parameter<\/b><\/td>\n<td><b>HIC<\/b><\/td>\n<td><b>SSC\/SSCC<\/b><\/td>\n<td><b>SOHIC<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Full term<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hydrogen-Induced Cracking<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Sulfide Stress Cracking<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Stress-Oriented Hydrogen-Induced Cracking<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Main concern<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hydrogen-induced internal cracking<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Cracking under tensile stress in H\u2082S environment<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hydrogen-assisted cracking influenced by stress orientation<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Typical relevance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Sour-service steels<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Sour-service materials exposed to H\u2082S<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Situations involving hydrogen charging and stress<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Relevant testing reference<\/span><\/td>\n<td><span style=\"font-weight: 400;\">NACE TM0284<\/span><\/td>\n<td><span style=\"font-weight: 400;\">NACE TM0177<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Discuss in relation to the applicable project\/test requirement<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Key consideration<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Crack morphology and ratios<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Resistance to cracking under specified test conditions<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Interaction between hydrogen and stress<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">NACE TM0284 itself states plainly that it evaluates HIC and does not address SSC, pitting or other sour-environment effects. One test result should never be read as automatic proof of compliance with a different cracking mechanism.<\/span><\/p>\n<h2><b>What Should Buyers Check When Ordering A516 Gr. 60 NACE Plates?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Start with the exact NACE specification called for on the project, whether that is MR0103, MR0175, or both. Confirm the HIC test requirement and which method applies, request the full material test certificate (MTC) with CLR, CTR and CSR values included, and check hardness requirements where the specification calls for them. Ask whether ultrasonic testing is specified for internal soundness, and verify heat and plate traceability back to the original cast. Match every acceptance criterion to the actual project document rather than a generic standard, since sour-service requirements vary by end-use application.<\/span><\/p>\n<h2><b>Selecting the Right A516 Gr. 60 NACE Plate<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The right plate comes down to matching the actual sour-service environment against the correct test requirement, not defaulting to whichever certificate happens to be on hand. HIC, SSC\/SSCC and SOHIC each address a different failure mode, and project specifications typically call out exactly which ones apply. RPF Pipes &amp; Fittings supplies <\/span><b>ASTM A516 Gr. 60 NACE MR 0103 Plates<\/b><span style=\"font-weight: 400;\"> and <\/span><b>ASTM A516 Gr. 60 NACE MR 0175 Plates<\/b><span style=\"font-weight: 400;\"> with documented test reports covering these requirements. Get in touch to confirm stock and test documentation for your project specification.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ASTM A516 Gr. 60 NACE Plates and Sour-Service Testing Wet H\u2082S environments break down ordinary carbon steel from the inside out. ASTM A516 Gr. 60 NACE MR 0103 Plates answer this problem in pressure vessels, separators and process equipment where sour service is part of daily operation. Hydrogen atoms generated by H\u2082S corrosion enter the &#8230; <a title=\"ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing\" class=\"read-more\" href=\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\" aria-label=\"More on ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":411,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[67,69,71,68,70,72,73],"class_list":["post-410","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-plates-blog","tag-a516-gr-70-nace-mr0103-plates","tag-a516-gr-70-sour-service-plates","tag-a516-gr-70-ssc-resistance","tag-astm-a516-grade-70-plates","tag-nace-mr0103-plates","tag-nace-mr0103-vs-a516-gr-70","tag-standard-a516-gr-70-plates"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.11 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ASTM A516 Gr. 60 NACE MR0103 Plates: HIC, SSCC &amp; SOHIC<\/title>\n<meta name=\"description\" content=\"Understand HIC, SSCC and SOHIC testing for ASTM A516 Grade 60 NACE MR0103 plates used in sour refinery environments.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ASTM A516 Gr. 60 NACE MR0103 Plates: HIC, SSCC &amp; SOHIC\" \/>\n<meta property=\"og:description\" content=\"Understand HIC, SSCC and SOHIC testing for ASTM A516 Grade 60 NACE MR0103 plates used in sour refinery environments.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\" \/>\n<meta property=\"og:site_name\" content=\"RPF Pipes &amp; Fittings\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-12T11:13:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-12T11:21:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hicplates.com\/blog\/wp-content\/uploads\/2026\/08\/ASTM-A516-Gr.-60-NACE-Plates-HIC-SSCC-SOHIC-Testing.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"749\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"RPF Pipes &amp; Fittings\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"RPF Pipes &amp; Fittings\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\"},\"author\":{\"name\":\"RPF Pipes &amp; Fittings\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/#\/schema\/person\/77bb23ee2d73a81d34d3e3015da6dfca\"},\"headline\":\"ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing\",\"datePublished\":\"2026-08-12T11:13:40+00:00\",\"dateModified\":\"2026-08-12T11:21:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\"},\"wordCount\":970,\"publisher\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/#organization\"},\"keywords\":[\"A516 Gr. 70 NACE MR0103 plates\",\"A516 Gr. 70 sour service plates\",\"A516 Gr. 70 SSC resistance\",\"ASTM A516 Grade 70 plates\",\"NACE MR0103 plates\",\"NACE MR0103 vs A516 Gr. 70\",\"standard A516 Gr. 70 plates\"],\"articleSection\":[\"plates blog\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\",\"url\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\",\"name\":\"ASTM A516 Gr. 60 NACE MR0103 Plates: HIC, SSCC & SOHIC\",\"isPartOf\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/#website\"},\"datePublished\":\"2026-08-12T11:13:40+00:00\",\"dateModified\":\"2026-08-12T11:21:26+00:00\",\"description\":\"Understand HIC, SSCC and SOHIC testing for ASTM A516 Grade 60 NACE MR0103 plates used in sour refinery environments.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hicplates.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/#website\",\"url\":\"https:\/\/www.hicplates.com\/blog\/\",\"name\":\"RPF Pipes &amp; Fittings\",\"description\":\"RPF Pipes &amp; Fittings\",\"publisher\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hicplates.com\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/#organization\",\"name\":\"RPF Pipes &amp; Fittings\",\"url\":\"https:\/\/www.hicplates.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.hicplates.com\/blog\/wp-content\/uploads\/2022\/04\/cropped-logo.png\",\"contentUrl\":\"https:\/\/www.hicplates.com\/blog\/wp-content\/uploads\/2022\/04\/cropped-logo.png\",\"width\":422,\"height\":50,\"caption\":\"RPF Pipes &amp; Fittings\"},\"image\":{\"@id\":\"https:\/\/www.hicplates.com\/blog\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/#\/schema\/person\/77bb23ee2d73a81d34d3e3015da6dfca\",\"name\":\"RPF Pipes &amp; Fittings\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.hicplates.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/14e4108de746b50bff420f29b7e7f9195ead38229a94df7f8e9f84f3506a2d0e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/14e4108de746b50bff420f29b7e7f9195ead38229a94df7f8e9f84f3506a2d0e?s=96&d=mm&r=g\",\"caption\":\"RPF Pipes &amp; Fittings\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ASTM A516 Gr. 60 NACE MR0103 Plates: HIC, SSCC & SOHIC","description":"Understand HIC, SSCC and SOHIC testing for ASTM A516 Grade 60 NACE MR0103 plates used in sour refinery environments.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/","og_locale":"en_US","og_type":"article","og_title":"ASTM A516 Gr. 60 NACE MR0103 Plates: HIC, SSCC & SOHIC","og_description":"Understand HIC, SSCC and SOHIC testing for ASTM A516 Grade 60 NACE MR0103 plates used in sour refinery environments.","og_url":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/","og_site_name":"RPF Pipes &amp; Fittings","article_published_time":"2026-08-12T11:13:40+00:00","article_modified_time":"2026-08-12T11:21:26+00:00","og_image":[{"width":1536,"height":749,"url":"https:\/\/www.hicplates.com\/blog\/wp-content\/uploads\/2026\/08\/ASTM-A516-Gr.-60-NACE-Plates-HIC-SSCC-SOHIC-Testing.png","type":"image\/png"}],"author":"RPF Pipes &amp; Fittings","twitter_card":"summary_large_image","twitter_misc":{"Written by":"RPF Pipes &amp; Fittings","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/#article","isPartOf":{"@id":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/"},"author":{"name":"RPF Pipes &amp; Fittings","@id":"https:\/\/www.hicplates.com\/blog\/#\/schema\/person\/77bb23ee2d73a81d34d3e3015da6dfca"},"headline":"ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing","datePublished":"2026-08-12T11:13:40+00:00","dateModified":"2026-08-12T11:21:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/"},"wordCount":970,"publisher":{"@id":"https:\/\/www.hicplates.com\/blog\/#organization"},"keywords":["A516 Gr. 70 NACE MR0103 plates","A516 Gr. 70 sour service plates","A516 Gr. 70 SSC resistance","ASTM A516 Grade 70 plates","NACE MR0103 plates","NACE MR0103 vs A516 Gr. 70","standard A516 Gr. 70 plates"],"articleSection":["plates blog"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/","url":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/","name":"ASTM A516 Gr. 60 NACE MR0103 Plates: HIC, SSCC & SOHIC","isPartOf":{"@id":"https:\/\/www.hicplates.com\/blog\/#website"},"datePublished":"2026-08-12T11:13:40+00:00","dateModified":"2026-08-12T11:21:26+00:00","description":"Understand HIC, SSCC and SOHIC testing for ASTM A516 Grade 60 NACE MR0103 plates used in sour refinery environments.","breadcrumb":{"@id":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.hicplates.com\/blog\/astm-a516-gr-60-nace-mr0103-plates-testing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hicplates.com\/blog\/"},{"@type":"ListItem","position":2,"name":"ASTM A516 Gr. 60 NACE Plates: HIC, SSCC &#038; SOHIC Testing"}]},{"@type":"WebSite","@id":"https:\/\/www.hicplates.com\/blog\/#website","url":"https:\/\/www.hicplates.com\/blog\/","name":"RPF Pipes &amp; Fittings","description":"RPF Pipes &amp; Fittings","publisher":{"@id":"https:\/\/www.hicplates.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hicplates.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.hicplates.com\/blog\/#organization","name":"RPF Pipes &amp; Fittings","url":"https:\/\/www.hicplates.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hicplates.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.hicplates.com\/blog\/wp-content\/uploads\/2022\/04\/cropped-logo.png","contentUrl":"https:\/\/www.hicplates.com\/blog\/wp-content\/uploads\/2022\/04\/cropped-logo.png","width":422,"height":50,"caption":"RPF Pipes &amp; Fittings"},"image":{"@id":"https:\/\/www.hicplates.com\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.hicplates.com\/blog\/#\/schema\/person\/77bb23ee2d73a81d34d3e3015da6dfca","name":"RPF Pipes &amp; Fittings","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hicplates.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/14e4108de746b50bff420f29b7e7f9195ead38229a94df7f8e9f84f3506a2d0e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/14e4108de746b50bff420f29b7e7f9195ead38229a94df7f8e9f84f3506a2d0e?s=96&d=mm&r=g","caption":"RPF Pipes &amp; Fittings"}}]}},"_links":{"self":[{"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/posts\/410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/comments?post=410"}],"version-history":[{"count":1,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/posts\/410\/revisions"}],"predecessor-version":[{"id":412,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/posts\/410\/revisions\/412"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/media\/411"}],"wp:attachment":[{"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/media?parent=410"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/categories?post=410"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hicplates.com\/blog\/wp-json\/wp\/v2\/tags?post=410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}